I-V(ZN)HH, UT-V(ZN)H(ZN)BH... | Breakout Cable |  |  | - 2, 4, 8, 12 or 24 single elements
| - Network Providers / Carrier
- LAN
- Harsh Environment
- Broadcast
- Data Center
|
|
I-F(ZN)H... | Fanout Cable |  |  | - 8-fold, 12-fold, 16-fold and 24-fold
- all usual plugs
- Strain relief and protection element on request
| - Network Providers / Carrier
- Data Center
|
Fanout CableVersions- 8-fold, 12-fold, 16-fold and 24-fold fanout cable assembled with MPO connectors one side and any common connector type on the other side
- Flame-retardant and halogen-free jacket
- Max. fanout length 5 m
- Protection and cable laying tube on request
- Assembly to ribbon cable on request
- Additional options on request
Design – Cable Divider- Cylindrical metal sleeve to protect the transition to the single breakout cables and to attach the pull cord, made of hollow tubing with strain relief
- Covered with shrinkable tubing for mechanical protection and to maintain the bending radius
- Optional protection and cable laying tube
Application | Singlemode | Multimode | MPO-12 / MTP® -12 | 40 GBASE-PSM4 100 GBASE-PSM4 200 GBASE-DR4 400 GBASE-DR4 800 GBASE-PSM8 (Dual MPO Interface) 800 GBASE-DR8 (Dual MPO Interface) | 40 GBASE-SR4 100 GBASE-SR4 200 GBASE-SR4 400 GBASE-SR4.2 800 GBASE-SR8 (Dual MPO Interface) | MPO-16 / MTP® -16 | 800 GBASE-PSM8 800 GBASE-DR8 | 400 GBASE-SR8 800 GBASE-SR8 | MPO-24 / MTP® -24 | | 100 GBASE-SR10 200 GBASE-2SR4 |
Advantages- Fanout cables in any length, one side or both sides pre-assembled
- 100% quality control, each product provided with test certificate
- Time saving during installation
- Assembly on location not necessary
- Direct connection to 19″ distribution technology possible
Fiber Types- E9/125 µm (OS2)
- G50/125 µm (OM2/OM3/OM4)
- G62,6/125 µm (OM1)
download datasheet MPO assembled to fanout cable MPO assembled to fanout cable Fanout cable, cross section |
4x I-F(ZN)H 2...... | FO Fanout Cable Direct Split |  |  | | - Network Providers / Carrier
- LAN
- Data Center
|
FO Fanout Cable Direct SplitVersions- MTP Connector assembled on 4 Duplex Patch Cable I-F(ZN)H 2
- Without Cable Divider for seperation to LC Uniboot or URM NG P2
- Base-8 System, suitable for 40 Gbit (4×10 Gbit) or 100 Gbit (4×25 Gbit)
- Flame-retardant and halogen-free jacket
- Additional options on request
Advantages- Time saving during installation
- Troublesome strain relief management is not necessary by using duplex patch cables
- By eliminating the rigid dividing element smallest bending radii can be realized
- Additional flexibility in the cable runs because of splitting the cable directly from the connector
- No shelfs for cable reserve needed because of custom-fit assemblies
Fiber Types- E9/125 µm (OS2)
- G50/125 µm (OM2/OM3/OM4)
download datasheet FO Fanout Cable Direct Split MTP to 4x URM NG P2 FO Fanout Cable Direct Split MTP to 4x LC Uniboot |
I-V(ZN)H... | Mini Breakout Cable |  |  | | - Network Providers / Carrier
- LAN
- Harsh Environment
- Broadcast
- Data Center
|
Mini Breakout Cable I-V(ZN)H…Design- Light, thin and flexible multi-fiber cable with halogen-free and flame-retardant jacket
- Applicable for direct connector assembly
Versions- Mini breakout cable with 12 single elements assembled with any connector type
- Diameter of single elements: 0.9 mm
- Protection and cable laying tube on request
- Other versions on request
Advantages- Mini breakout cables in any length, one side or both sides pre-assembled
- 100% quality control, each product provided with test certificate
- Time saving during installation
- Assembly on location not necessary
- Direct connection to 19″ distribution technology possible
Fiber Types- E9/125 μm (OS2)
- G50/125 μm (OM2/OM3/OM4)
- G62.5/125 μm (OM1)
|
I-D(ZN)BH, U-DQ(ZN)BH, A-DQ(ZN)B2Y... | Multi Loose Tube Cable with Cable Dividing Element |  |  | - 2-fold to 144-fold cable divider, max. whip length 5 m
- Cable gland on request
| - Network Providers / Carrier
- LAN
- Harsh Environment
- Broadcast
- Data Center
|
Multi Loose Tube Cable with Cable Dividing ElementDesign- 2-fold to 144-fold cable dividing element available with any type of fiber optic connector
- Max. fanout cable length: 5 m
- Assembled cable can be delivered on a one-way drum
- Protection and cable laying tube on request
- Indoor, outdoor or universal cable
- Others on request
Advantages- Multi loose tube cables in any length, one side or both sides pre-assembled
- 100% quality control, each product provided with test certificate
- Assembly on location not necessary
- Direct connection to 19″ distribution technology possible
Fiber Types- E9/125 μm (OS2)
- G50/125 μm (OM2/OM3/OM4)
- G62.5/125 μm (OM1)
download datasheet Multi loose tube cable with cable dividing element Multi loose tube cable OM4 Multi loose tube cable, cross section |
I-B(ZN)BH...... | Multi Loose Tube Cable with Cable Dividing Element – gel-free |  |  | | - Network Providers / Carrier
- LAN
- Data Center
|
Multi Loose Tube Cable with Cable Dividing Element – gel-freeDesign- LWL Indoorcable available with up to 144 fibers with any type of fiber optic connector (e.g. MTP®, LC)
- Max. fanout cable length: 5 m
- I-B(ZN)BH nx12…
- Others on request
Advantages- Multi loose tube cables in any length, one side or both sides pre-assembled
- 100% quality control, each product provided with test certificate
- Assembly on location not necessary
- Direct connection to 19″ distribution technology possible
Fiber Types- E9/125 μm (OS2)
- G50/125 μm (OM2/OM3/OM4)
- G62.5/125 μm (OM1)
|
Standard... | Protection and Cable Laying Tube Standard |  | | - Tensile load up to 600 N, higher values on request
| - Network Providers / Carrier
- Harsh Environment
- Broadcast
- Data Center
|
Protection and Cable Laying Tube – StandardApplication- Breakout cable and multi loose tube cable
Design- Plastic corrugated tube as connector and breakout cable protection, fixed with shrinkable tubing on the cable jacket behind cable exit
- Outer diameter 25 mm to 45 mm
(depending on the number of single cables and the assembled connectors) - The assembled connectors are staggered as a group of 2, 4 or 6
- Standard length of single elements is 100 cm
- Other arrangements and lengths on request
- Pullcord attached at cable jacket and exiting at the front of the protection tubing
Max. Tensile StrengthTensile strength on the pullcord: - 300 N for breakout cable and mini breakout cable
- 600 N for multi loose tube cable
- Higher values on request
- Apply tensile load at cable jacket for higher values
(see data sheet of cable manufacturer)
Number of fibers / cables | Connector grouping | Outer diameter protection element |
---|
2 to 12 | 2 | 25 mm (30 mm*) |
---|
14 to 24 | 4 | 35 mm |
---|
26 to 48 | 6 | 45 mm |
---|
| *Fanout length > 1.5 m |
---|
|
Undetachable... | Protection and Cable Laying Tube Undetachable for Mobile Cable Drum |  | | - Undetachably fixed protection and cable laying tube primarily for cable drums
| - Harsh Environment
- Broadcast
|
Protection and Cable Laying Tube – UndetachableApplicationDesign- Plastic corrugated tube as connector and breakout cable protection, fixed with cable glands at the cable jacket behind the cable exit
- Outer diameter 38 mm to 45 mm
(depends on the number of single cables and the assembled connectors) - The assembled connectors are staggered as a group of 2 or 4
- Standard length of the single elements is 100 cm
- Other arrangements and lengths on request
- Pullcord attached at cable jacket and exiting at the front of the protection tubing
Max. Tensile StrengthTensile strength on the pullcord: 300 N for breakout and minibreakout cable 600 N for multi loose tube cable Higher values on request Apply tensile load at cable jacket for higher values (see data sheet of cable manufacturer)
Number of fibers / cables | Connector grouping | Outer diameter protection element |
---|
2 to 12 | 2 | 38 mm |
---|
14 to 24 | 4 | 45 mm |
---|
|
Reusable... | Reusable Fixed Protection and Cable Laying Tube |  | | - Reusable fixed protection and cable laying tube
| - Harsh Environment
- Broadcast
|
Protection and Cable Laying Tube – ReusableApplicationDesign- Plastic corrugated tube as connector and breakout cable protection, fixed with a screw joint with swivel female thread
- Protection class IP67
- Outer diameter 38 mm or 45 mm
(depends on the number of single cables and the assembled connectors) - The assembled connectors are staggered as a group of 2 or 4
- Standard length of the single elements is 100 cm
- Other arrangements and lengths on request
Max. Tensile StrengthNumber of fibers / cables | Connector grouping | Outer diameter protection element |
---|
2 to 12 | 2 | 38 mm |
---|
14 to 24 | 4 | 45 mm |
---|
|
I-V(ZN)HH nx8... | Trunk Cable |  |  | | |
Trunk Cable I-V(ZN)HH nx8Design- Round cable
- Stranded breakout construction
- Up to 128 fibers in one cable, spread over 16 elements
Properties- Indoor cable
- Main component is a single element with 8 fibers enclosed with URM P8 multi fiber connector
- High packing density
- Low cable load
- Breakout cable with 4, 8 or 16 single elements
- Singlemode and multimode (OS2, OM2, OM3, OM4) available
- Flame-retardant and non-corrosive jacket
- Convenient installation
- Ideal bending radius for fibers
- Cable length according to customer request
Application- Laying in false floors or cable routes (backbone cabling)
- Floor cabling is also possible
- Medium to long lines
Thermal Properties- Transport and storage: -25 to +70°C
- Installation: -5 to +50°C
- Operating: -5 to +70°C
FiberTypes- E9/125 μm (OS2)
- G50/125 μm (OM2/OM3/OM4)
- G62.5/125 μm (OM1)
Technical Data | 8-fold | 32-fold | 64-fold | 128-fold |
---|
Number of elements | 1 x 8 | 4 x 8 | 8 x 8 | 16 x 8 |
---|
Number of fibers | 8 | 32 | 64 | 128 |
---|
Outer diameter [mm] | 3.5 | 10.5 | 14.8 | 18.5 |
---|
Max. tensile strength [N] | 600 | 1,200 | 1,200 | 1,200 |
---|
Crush resistance [N/dm] | 200 | 1,000 | 1,000 | 1,000 |
---|
Cable weight [kg/km] | 15 | 90 | 155 | 255 |
---|
Bending radius (operating) | 10 x D | 10 x D | 10 x D | 10 x D |
---|
Bending radius (installation) | 15 x D | 15 x D | 15 x D | 15 x D |
---|
|
I-V(ZN)HH nx2... | Trunk Cable (Multi Jumper Cable) |  |  | - 2x2 / 4x2 / 8x2 16x2 / 24x2 / 32x2 verfügbar
| |
Trunk Cable (Multi Jumper Cable) I-V(ZN)HH nx2Design- Round cable
- Stranded breakout construction
Properties- 2, 4, 8, 16, 24 and 32-fold
- Breakout cable, consists of single elements with 2 fibers
- Singlemode and multimode (OS2, OM2, OM3, OM4) available
- Flame-retardant, non-corrosive jacket
- Convenient installation
- Ideal bending radius for fibers
- Cable length according to customer request
- Indoor cable
Application- Suitable for direct connection of active devices, can also be used alternatively for connecting a device to a patch panel
- Also suitable for cable routes and, thus, for connection of different areas
- Suitable for connection of two data racks as well
- For short to medium distances
- Alternative type for trunk cabling
Thermal Properties- Transport and storage: -25 to +70°C
- Installation: -5 to +50°C
- Operating: -5 to +70°C
Technical Data | 2-fold | 4-fold | 8-fold | 16-fold | 24-fold | 32-fold |
---|
Number of elements | 2 x 2 | 4 x 2 | 8 x 2 | 16 x 2 | 24 x 2 | 32 x 2 |
---|
Number of fibers | 4 | 8 | 16 | 32 | 48 | 64 |
---|
Outer diameter [mm] | 6.1 | 6.1 | 12.5 | 10.9 | 13.5 | 14.7 |
---|
Max. tensile strength [N] | 400 | 1,000 | 1,600 | 1,200 | 1,600 | 2,000 |
---|
Crush resistance [N/dm] | 600 | 1,000 | 1,000 | 1,000 | 1,000 | 1,000 |
---|
Cable weight [kg/km] | 30 | 35 | 120 | 110 | 130 | 190 |
---|
Bending radius (operating) | 10 x D | 10 x D | 10 x D | 10 x D | 10 x D | 10 x D |
---|
Bending radius (installation) | 15 x D | 15 x D | 15 x D | 15 x D | 15 x D | 15 x D |
---|
|
U-DQH nx8... | URM Trunk Cable with Cable Dividing Element |  |  | | |
URM Trunk Cable with Cable Dividing ElementProperties- FO trunk cable assembled with URM P8 connectors on both sides
- Quickly and easily installable in the data center
- Base-8 system, suitable for 40 Gbit (4×10 Gbit) or 100 Gbit (4×25 Gbit)
- High packing density
- Low cable load
- Universal cable: flame retardant and halogen-free jacket
- Comfortable fixing of the trunk cable in subracks, patch- or splice boxes with integrated cable gland on the cable divider
Thermal properties- Installation -5°C to +50°C
- Operating -5°C to +70°C
- Transportation and storage -25°C to +70°C
Fiber Types- E9/125 μm (OS2 bend optimized)
- G50/125 μm (OM4 bend optimized))
Technical Data | 32- fold | 64- fold | 96- fold | 128- fold |
---|
Number of cores | 4 x 8 | 8 x 8 | 12 x 8 | 16 x 8 |
---|
Number of fibers | 32 | 64 | 96 | 128 |
---|
Diameter of cable [mm] | 10.5 | 12.0 | 15.0 | 16.5 |
---|
Tensile strength max. [N] | 1,800 | 1,800 | 1,800 | 1,800 |
---|
Crush resistance constant [N/dm] | 3,000 | 3,000 | 3,000 | 3,000 |
---|
Cable weight [kg/km] | 90 | 125 | 190 | 230 |
---|
Bending radius [mm] | 160 | 180 | 225 | 250 |
---|
download datasheet URM Trunk cable URM Cable dividing element URM Patch box fitted with the trunk cable Trunk cable, cross section |