Blown Fiber Micro Cable |  | - Suitable for microducts
- Up to 24 fibers
| - Network Providers / Carrier
- FTTH
|
Blown Fiber Micro Cable- Up to 24 fibers
- Metall-free Outdoor cable with central loose tube
- Polyethylen outer jacket (HDPE)
Applications- In the FTTX market
- Designed to be installed by blowing into microducts
Technical data of a typical Blown Fiber Micro CableLabeling | A-DQ(ZN)2Y 1xn… |
---|
Standardization | IEC 60793, IEC60794-5-10 |
---|
Composition | Cable core | Loose tube, gel-filled |
---|
Strain relief | Non-metallic (aramid) | Cable jacket | HDPE | Color of jacket | Black | Cable diameter | 2.5 mm |
---|
Tensile strength | 200N |
---|
Crush resistance | 500 N/dm |
---|
Temperature range | Operating temperature | -20°C to +70°C |
---|
Storage temperature | -40°C to +70°C | Installation | -5°C to +60°C |
|
FO Outdoor Cable for Mobile Use |  | - Abrasion-proof and useable on mobile cable drums
- Rugged cable for use in harsh environment
| - Harsh Environment
- Broadcast
|
FO Outdoor Cable for Mobile Use- Abrasion-proof and reelable in a wide temperature range
- Polyurethane (PUR) cable jacket
- High mechanical robustness
Applications- Mobile cable drums for broadcast, defense and security
- Harsh environment applications
- Suitable for drag chains
Wide range of different cables available, e.g.- U-DQ(ZN)11Y n…
- A-V(ZN)11Y(ZN)11Y 2…
- A-V(ZN)11Y(ZN)11Y 4…
————– Seitenumbruch im PDF ————–
Technical data of a typical outdoor cable for mobile useLabeling | U-DQ(ZN)11Y n… |
---|
Manufacturer | LEONI Fiber Optics GmbH |
---|
Standardization | IEC 60794-2 |
---|
Fire performance | IEC 60754-1 (absence of halogen) |
---|
IEC 60754-2 (acidity of combustion gases) | Composition | Cable core | Loose tube, gel-filled |
---|
Strain relief | Non-metallic (aramid) | Cable jacket | PUR | Color of jacket | Black | Outer diameter | 6.5 mm or 7.7 mm (depends on numbers of fibers) |
---|
Tensile strength | 2,500 N (on jacket) |
---|
Crush resistance | 3,000 N/dm |
---|
Temperature range | Operating temperature | -25°C to +70°C |
---|
Storage temperature | -25°C to +70°C | Installation | -25°C to +50°C |
|
HCS / PCF Cable |  | - Glass core fiber with polymer cladding
- Easy use
- Glass core fiber with polymer cladding
| |
HCS / PCF Cable- Fiber optic cable with HCS / PCF
- (Hard Clad Silica Optic Fiber / Polymer Clad Fiber)
- Typical attenuation ≤ 8 dB/km (850 nm)
(depends on fiber) - High mechanical robustness and easy to assemble
Applications- Flexible installation in harsh industrial environments (indoor and outdoor)
- Automobile technology
- Medical technology
Wide range of different cables available, e.g.- I-V(ZN)H 1G100/140
- I-V(ZN)Y 1K200/230
- AT-V(ZN)Y11Y 2K200/230
Technical data of a typical HCS / PCF cableLabeling | I-V(ZN)H 2x1K200/230 |
---|
Manufacturer | LEONI Fiber Optics GmbH |
---|
Composition | Cable core | 2 PCF-elements |
---|
Strain relief | Non-metallic (aramid) | Cable jacket | Halogen-free and flame-retardant material | Color of jacket | Multimode: orange Singlemode: yellow | Outer diameter | 2.2 x 4.5 mm |
---|
Tensile strength | 300 N (short-term) |
---|
Temperature range | Operating temperature | -20°C to +70°C |
---|
Attenuation | At 650 nm (Laser) | ≤ 10 dB/km |
---|
At 850 nm (LED) | ≤ 8 dB/km |
|
Indoor Cable e.g. I-V(ZN)… |  | - Flexibility, reduced weight and small outer diameter
- Fulfil the strict fire prevention requirements for indoor installation
| - Network Providers / Carrier
- LAN
- Data Center
|
Indoor Cable- Highly flexible cable with small bending radius, low weight and small diameter
- Halogen-free and flame-retardant cable jacket
- Fulfills fire prevention requirements DIN EN and IEC for indoor use
Applications- Primary, secondary and tertiary cabling of buildings
- Patch cable for datacenters
Wide range of different indoor cables available, e.g.- I-V(ZN)H 1…
- I-V(ZN)H 2 x 1…
- I-V(ZN)HH 2 x 1…
- I-V(ZN)HH n…
- I-D(ZN)H …
————– Seitenumbruch im PDF ————–
Technical data of a typical indoor cableLabeling | I-V(ZN)H 1… |
---|
Manufacturer | LEONI Fiber Optics GmbH |
---|
Standardization | IEC 60794-2 |
---|
Fire performance | IEC 60332-1-2 and IEC 60332-3-22 Cat. A (flame-retardant) |
---|
IEC 61034 (smoke density) | IEC 60754-1 (absence of halogen) | IEC 60754-2 (acidity of combustion gases) | Composition | Cable core | Tight buffered or semi-tight buffered fiber |
---|
Strain relief | Non-metallic (aramid) | Cable jacket | Halogen-free and flame-retardant material | Color of jacket | Orange for multimode Yellow for singlemode | Outer diameter | 1.6 mm to 3.4 mm |
---|
Tensile strength | 200 N (others on request) |
---|
Crush resistance | 100 N/dm (others on request) |
---|
Temperature range | Operating temperature | -10°C to +70°C |
---|
Storage temperature | -25°C to +70°C | Installation | -5°C to +50°C |
|
Outdoor Cable e.g. A-DQ(ZN)… |  | - High resistance to environmental influences and rodent
- High mechanical robustness
| - Network Providers / Carrier
- Harsh Environment
|
Outdoor Cable- Resistance to environmental influences (frost, humidity, rodents)
- Outdoor jacket, UV-resistant and halogen-free
- Non-metallic or metallic protection against rodents
- High mechanical robustness
- Suitable for stationary installation
Applications- Campus area of local area networks
- Bridging for long distances (MAN, WAN)
Wide range of different outdoor cables available, e.g.- A-DQ(ZN)B2Y n x m…
- A-D(ZN)2Y n…
- A-DQ(ZN)(SR)2Y n x m…
- AT-V(ZN)H(ZN)BH n…
————– Seitenumbruch im PDF ————–
Technical data of a typical outdoor cableLabeling | A-DQ(ZN)B2Y n x m… |
---|
Manufacturer | LEONI Fiber Optics GmbH |
---|
Standardization | IEC 60794-3 |
---|
Fire performance | IEC 60754-1 (Absence of halogen) |
---|
IEC 60754-2 (Acidity of combustion gases) | Composition | Cable core | GFR strength member Gel-filled loose tubes |
---|
Armor | Glass roving | Cable jacket | Polyethylene | Color of Jacket | Black | Outer diameter | 11.4 mm to 20.2 mm (depends on number of fibers) |
---|
Tensile strength | 4,000 N (others on request) |
---|
Crush resistance | 3,000 N/dm (others on request) |
---|
Temperature range | Operating temperature | -40°C to +60°C |
---|
Storage temperature | -40°C to +70°C | Installation | -5°C to +50°C |
|
POF Cable |  | - Polymer fiber cor with polymer cladding
- Economical alterativ to fiber of glass
| |
POF Cable- Fiber optic cable with POF (Polymer Optic Fiber)
- Typical attenuation ≤ 180 dB/km (650 nm)
(depends on fiber) - Cover distances up to 150 m by data transmissions
Applications- Industrial use (indoor and outdoor)
- Suitable for drag chains
- Hybrid cables
Wide range of different cables available, e.g.- V-2Y 1P980/1000
- I-V2Y(ZN)11Y 1P980/1000
- I-V4Y(ZN)Y 2P980/1000
Technical data of a typical POF cableLabeling | I-V2Y(ZN)11Y 1P980/1000 6.0 mm |
---|
Manufacturer | LEONI Fiber Optics GmbH |
---|
Composition | Cable core | 1 POF element with buffer tube consisting of PE |
---|
Strain relief | Non-metallic (aramid) | Cable jacket | PUR | Color of jacket | Red | Outer diameter | 6.0 mm |
---|
Tensile strength | 400 N (short-term) |
---|
Temperature range | Operating temperature | -20°C to +70°C |
---|
Attenuation | At 650 nm (Laser) | ≤ 160 dB/km |
---|
At 660 nm (LED) | ≤ 230 dB/km |
|
Universal Cable e.g. U-D(ZN)BH… |  | - For indoor and outdoor use
- Fulfil fire prevention requirements for indoor installation
| - Network Providers / Carrier
- LAN
- Harsh Environment
- Data Center
|
Universal Cable- For indoor and outdoor use
- Halogen-free and flame-retardant cable jacket
- Fulfills fire prevention requirements DIN EN and IEC for indoor use
Applications- Secondary and tertiary cabling of buildings
- Cabling between campus area and buildings
- Suitable for stationary cabling
Wide range of different universal cables available, e.g.- U-D(ZN)BH n…
- U-DQ(ZN)BH n x m…
- U-VQ(ZN)BH n…
————– Seitenumbruch im PDF ————–
Technical data of a typical universal cableLabeling | U-DQ(ZN)BH n x m… |
---|
Standardization | IEC 60794-2, EN 50 173-1, ISO 11801-2 |
---|
Manufacturer | Leoni Fiber Optics GmbH |
---|
Fire performance | IEC 60332-1-2 |
---|
IEC 61034 (smoke density) | IEC 60754-2 (acidity of combustion gases) | Composition | Cable core | GFR strength member Loose tubes |
---|
Armor | Glass roving | Cable jacket | Halogen-free, UV-resistant and flame-retardant material | Color of jacket | Blue | Outer diameter | 11.0 mm to 15.5 mm (depends on number of fibers) |
---|
Tensile strength | 5,000 N (temporary) |
---|
Crush resistance | 3,000 N/dm (others on request) |
---|
Temperature range | Operating temperature | -40°C to +70°C |
---|
Storage temperature | -40°C to +70°C | Installation | -40°C to +70°C |
|